quadEM  7-0
Macros | Functions
drvAHxxx.cpp File Reference
#include <stdlib.h>
#include <string.h>
#include <stdio.h>
#include <errno.h>
#include <math.h>
#include <epicsTypes.h>
#include <epicsTime.h>
#include <epicsThread.h>
#include <epicsString.h>
#include <epicsTimer.h>
#include <epicsMutex.h>
#include <epicsEvent.h>
#include <asynOctetSyncIO.h>
#include <iocsh.h>
#include <epicsExport.h>
#include "drvAHxxx.h"

Macros

#define AHxxx_TIMEOUT   0.05
 
#define MIN_INTEGRATION_TIME   0.001
 
#define MAX_INTEGRATION_TIME   1.0
 

Functions

int drvAHxxxConfigure (const char *portName, const char *QEPortName, int ringBufferSize, const char *modelName)
 EPICS iocsh callable function to call constructor for the drvAHxxx class. More...
 
void drvAHxxxRegister (void)
 
 epicsExportRegistrar (drvAHxxxRegister)
 

Macro Definition Documentation

#define AHxxx_TIMEOUT   0.05
#define MAX_INTEGRATION_TIME   1.0
#define MIN_INTEGRATION_TIME   0.001

Function Documentation

int drvAHxxxConfigure ( const char *  portName,
const char *  QEPortName,
int  ringBufferSize,
const char *  modelName 
)

EPICS iocsh callable function to call constructor for the drvAHxxx class.

Parameters
[in]portNameThe name of the asyn port driver to be created.
[in]QEPortNameThe name of the asyn communication port to the AHxxx created with drvAsynIPPortConfigure or drvAsynSerialPortConfigure.
[in]ringBufferSizeThe number of samples to hold in the input ring buffer. This should be large enough to hold all the samples between reads of the device, e.g. 1 ms SampleTime and 1 second read rate = 1000 samples. If 0 then default of 2048 is used.
[in]modelNameThe model of electrometer. It is too difficult to try to determine this from the firmware version number, so it must be specified. Allowed values are: "AH401B", "AH401D", "AH501", "AH501BE", "AH501C", and "AH501D".
void drvAHxxxRegister ( void  )